Configuring and Managing Host-Based X.25 Links - Edition 5 (36939-90054)

94 Chapter4
Terminal and Printer Profiles
DTC PAD Profile Field
DTC PAD Profile Field
The profile number used by the PAD is the decimal value of the binary
number calculated from Table 4-3 as done by the
[Compute Byte]
function key. An “x” in a box means that the value doesn’t matter: that
is, the values of the bits are not dependent on each other. Bit 7 is
reserved for future use, and is set to 0. Note that you can only use
certain combinations: meaningless or dangerous combinations are
blocked and cannot be entered.
Terminal with init profile set; Bit 0 is 1 = 1
Data forwarding 3:127 4:0; Bit 1 is 1 = 4
X.3 setting allowed; Bit 4 is 0 = 0
No PAD test during connection initialization; Bit 5 is 1 = 32
Profile number = 37
Table 4-3 PAD Profile Field
7 6 5 4 3210 Bit Position
(128) (64) (32) (16) (8) (4) (2) (1) (Bit Value)
0 x x x x x 0 0 Printer without init profile set
0 x x x x x 0 1 Terminal with init profile set
0 x x x x x 1 0 Printer with init profile set
0 x x x x x 1 1 Terminal without init profile set
0 x x x 0 0 x x Data forwarding default
0 x x x 0 1 x x Data forwarding 3:127 4:0
0 x x x 1 0 x x Data forwarding 4:1
0 x x x 1 1 x x Data forwarding 4:2
0 x x 0 xxxxX.3 setting
0 x x 1 xxxxNo X.3 setting
0 x 0 x xxxxPAD test during connection initialization
0 x 1 x xxxxNo PAD test during connection initialization
0 0 x x xxxxNo forced data forwarding
0 1 x x xxxxForced data forwarding