NS3000/iX Error Messages Reference Manual (36923-90043)

140 Chapter14
VALERR and VALWARN Messages
325 MESSAGE: X.25 ADDRESS address is defined more than once.
CAUSE: An X.25 address is defined more than once under the
NETXPORT.NI.NIname.PROTOCOL.X25.SVCPATH path.
ACTION: Make sure all X.25 addresses are unique in a given SVC
configuration path.
350 MESSAGE: MORE THAN 1024 SVCPATHS CONFIGURED.
CAUSE: The number of SVC entries under the
NETXPORT.NI.NIname.PROTOCOL.X25.SVCPATH path exceeds the
maximum of 1024 allowed.
ACTION: Delete the excess SVC entries.
351 MESSAGE: MORE THAN 128 PVCPATHS CONFIGURED.
CAUSE: The number of PVC entries under the
NETXPORT.NI.NIname.PROTOCOL.X25.PVCPATH path exceeds the
maximum of 128 allowed.
ACTION: Delete the excess PVC entries.
900 MESSAGE: COULD NOT BUILD PATH REPORT FOR CONFIGURATION
FILE.
CAUSE: An internal error occurred while building the local node's path
report to place in the configuration file.
ACTION: RESTORE a backup copy of NMCONFIG.PUB.SYS from tape and
try to validate the Network Transport again. If this fails, the
configuration file is corrupt. See Appendix A , “Submitting a CR,” of this
manual.
901 MESSAGE: COULD NOT ADD PATH REPORT TO CONFIGURATION
FILE.
CAUSE: An internal error occurred while adding the local node's path
report to the configuration file.
ACTION: RESTORE a backup copy of NMCONFIG.PUB.SYS from tape and
try to validate the Network Transport again. If this fails, the
configuration file is corrupt. See Appendix A , “Submitting a CR,” of this
manual.
1004 MESSAGE: NO STORE AND FORWARD BUFFERS CONFIGURED.
CAUSE:
1. The specified router network has more than one link configured, but
no store and forward buffers have been configured in the
NETXPORT.NI.NIname.PROTOCOL.IP screen. It will not be possible to
send inbound packets from one link out to another link without any
store and forward buffers.