NS3000/iX Error Messages Reference Manual (36923-90043)

182 Chapter16
100VG-AnyLAN and HP-PB 100Base-T Error Messages
SDI Driver Specific Status Values
matches the path where a supported 100VG-AnyLAN or HP-PB
100Base-T adapter card is installed in your computer backplane. If the
path passes through bus converters, verify the SYSGEN configuration
has entries for the higher-level bus converters leading to that path. If
necessary, change NMCONFIG or contact your Hewlett-Packard
Representative for assistance in determining paths or correcting bus
hardware problems.
86 ($56) MESSAGE: Cannot remove driver from I/O system.
CAUSE: During the final link-close operation by an upper level
subsystem, the link module deconfigurator attempted to delete an
instance of the link driver, but encountered an I/O system error.
ACTION: Not all resources were released. The driver may already have
been shut down by some other means, or the system I/O configuration
may have been altered. If this happens frequently, see Appendix A ,
“Submitting a CR.
87 ($57) MESSAGE: Cannot load a system routine.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to load code
for the write initiator procedure needed for the link type configured in
NMCONFIG.
ACTION: Probably not all software required to operate this type of link
is installed. Software was incorrectly installed, or you may need to
purchase additional software or install newer patches. Reinstall the
link software or contact your Hewlett-Packard Representative for
assistance.
88 ($58) MESSAGE: Cannot open NM logging.
CAUSE: During a link open attempt by an upper-level subsystem, the
link module configurator encountered a positive (error) status when
trying to open NM logging against the link’s subsystem ID.
ACTION: This event is informational. No action is required. The module
configurator cleared the error and will attempt to continue. However,
NM logging may not be available to the link. You may need to install
new NM logging patches. If the problem occurs every time, see
Appendix A , “Submitting a CR.
89 ($59) MESSAGE: Cannot freeze a memory area.
CAUSE: This is a generic error that during a link-open or some other
operation by an upper level subsystem, link software encountered an
error while trying to freeze some data into memory before passing the
driver a pointer to that data.
ACTION: The system may be low on available memory. Try closing any
unnecessary applications or sessions and retry the operation.