NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 16 199
100VG-AnyLAN and HP-PB 100Base-T Error Messages
SDI Driver Specific Status Values
244 ($F4) MESSAGE: Error encountered while decoding an entry.
CAUSE: The trace or log formatter encountered an entry having an
unrecognized entry tag value. The formatter cannot decode entries of
this type.
ACTION: The formatter will attempt to print this entry in raw form. You
may be trying to format a trace or log file taken on a different system
that has newer software than the system you are formatting on. Format
the file on the system you took the trace or log on, or contact your
Hewlett-Packard Representative to check if VGFOS patches are
already available to correct this problem.
245 ($F5) MESSAGE: Incomplete data was encountered.
CAUSE: The trace or log formatter attempted to decode an entry, but on
inspection found that the entry did not contain at least the minimum
length of data required for this version of the data.
ACTION: The trace or log file may be corrupted, or you may be trying to
format a trace or log file taken on a different system that has newer
software than the system you are formatting on. The formatter will
attempt to print this entry in raw form. Format the file on the system
you took the trace or log on, or contact your Hewlett-Packard
Representative to check if VGFOS patches are already available to
correct this problem.
Logging Sublocation Codes
The following are the logging sublocation codes reported by the
100VG-AnyLAN and HP-PB 100Base-T link drivers, including
sublocation code, log class, log message, and the appropriate cause of
and action to take for each.
For meanings of 32-bit status values generated by the driver, refer to
the sections on status values.
1020 CLAS0001 MESSAGE: Cannot freeze a memory area.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator was preparing to send configuration data to
the driver, but encountered an error while trying to freeze that data
into memory (“Cause” = 32-bit status from the call to freeze).
ACTION: The system may be low on available memory. Try closing any
unnecessary applications or sessions and retry the operation. The open
did not succeed. The module configurator cleaned up and returned an
error to the subsystem.
1040 CLAS0001 MESSAGE: Cannot send a port message.
CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator was preparing to send configuration data to
the driver, but encountered an error while trying to send the port