NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 16 237
100VG-AnyLAN and HP-PB 100Base-T Error Messages
SDI Driver Specific Status Values
available. It is unlikely this would be caused by a system HP-PB bus
hardware problem.
5030 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: While attempting to alter the loopback mode during diagnostic
testing, the driver read from the network command register on the LAN
controller chip of the adapter card, but encountered an error. Most
likely a power failure has occurred (“Cause” = 32-bit status returned by
the call to vg_dio_read8).
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. But if the same
problem happens every time, see Appendix A , “Submitting a CR.
5060 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: While attempting to alter the loopback mode during diagnostic
testing, the driver read from the generic control register on the PHY
chip of the adapter card, but encountered an error. Most likely the PHY
has failed, but a power failure may have occurred (“Cause” = 32-bit
status returned by the call to vg_mii_read16).
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.
5090 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: While attempting to alter 100VG-AnyLAN loopback mode
during diagnostic testing, the driver read from the PHY control register
on the PHY chip of the adapter card, but encountered an error. Most
likely the PHY has failed, but a power failure may have occurred
(“Cause” = 32-bit status returned by the call to vg_mii_read16).
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.
5120 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: While attempting to alter HP-PB 100Base-T loopback mode
during diagnostic testing, the driver read from a loopback control
register on the PHY chip of the adapter card, but encountered an error.
Most likely the PHY has failed, but a power failure may have occurred
(“Cause” = 32-bit status returned by the call to vg_mii_read16).
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.