NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 16 247
100VG-AnyLAN and HP-PB 100Base-T Error Messages
SDI Driver Specific Status Values
6110 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: During a HP-PB 100Base-T connect sequence after the link
came up, the driver attempted to check the final connect settings, but
encountered an error trying to read from the autonegotiation
advertisement register on the PHY chip (“Cause” = 32-bit status from
the call to vg_mii_read16). Most likely a powerfail has occurred.
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.
6140 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: During a HP-PB 100Base-T connect sequence after the link
came up, the driver attempted to check the final connect settings, but
encountered an error trying to read from the link partner capabilities
register on the PHY chip (“Cause” = 32-bit status from the call to
vg_mii_read16). Most likely a powerfail has occurred.
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.
6170 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: During a HP-PB 100Base-T connect sequence after the link
came up, the driver attempted to check the final connect settings, but
encountered an error trying to read from the autonegotiation expansion
register on the PHY chip (“Cause” = 32-bit status from the call to
vg_mii_read16). Most likely a powerfail has occurred.
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.
6180 CLAS0001 MESSAGE: Driver encountered a hardware problem.
CAUSE: During a HP-PB 100Base-T connect sequence after the link
came up, the driver attempted to check the final speed and duplex
settings, but encountered an error trying to read from the PHY address
register on the PHY chip (“Cause” = 32-bit status from the call to
vg_mii_read16). Most likely a powerfail has occurred. This error
cannot occur on older PHY chips.
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A , “Submitting a CR.