Probably the link driver returned an error reply when asked to enable
tracing. The driver may have a problem. Check for other, driver-specific
error messages which may give more information about the problem,
and look them up also. If no other errors are found, see Appendix A ,
“Submitting a CR.
1620 CLAS0001 MESSAGE: The subsys link products are not installed.
CAUSE: Probably not all software required to operate this type of link is
installed. Software was incorrectly Installed, or you may need to
purchase additional software or install new patches.
ACTION: If this status is reported during a startup operation, Reinstall
the link software or contact your HP Representative for assistance.
1640 CLAS0001 MESSAGE: Cannot release a system plabel.
CAUSE: During the link startup operation by an upper level subsystem,
the link module configurator encountered an error while trying to
release the link’s key routine procedure (“Cause” = 32-bit status from
the call to hprelsysplabel).
ACTION: This is an informational warning that some system memory
resources may have been lost. The module configurator reported an
error, but attempted to continue with the open. If this happens every
time, see Appendix A , “Submitting a CR.
1660 CLAS0001 MESSAGE: Module Configurator cannot get its context area.
CAUSE: During the link start up process, the module configurator tries
to configure the Download Surrogate and encountered an error where it
got the surrogate’s port number as Nil.
ACTION: This is an error. Try to restart the link again. If the problem
persists with a know good card, see Appendix A , “Submitting a CR.
1680 CLAS0001 MESSAGE: The link is already started.
CAUSE: During the first link-open operation by an upper level
subsystem, the link module configurator attempted to create a new
instance of the link driver, but discovered the driver was already
created and has been opened at least once (“Cause” = 32-bit status from
the call to io_configure, saying the link is already started).
ACTION: This is an informational warning only. The module
configurator will leave the link driver up and stop trying to start it
again. Usually preceded by another error.
1700 CLAS0001 MESSAGE: Error in configuring download surrogate.
CAUSE: During the first link-open operation by an upper level
subsystem, the link module configurator attempted to create a new
instance of the link driver, but discovered the driver was already
created and has been opened at least once (“Cause” = 32-bit status from
the call to io_configure, saying the link is already started).