NS3000/iX Error Messages Reference Manual (36923-90043)

424 Chapter18
PCI LAPBMUX Link Error Messages
SDI Driver Specific Status Values
ACTION: None. This error can be ignored. Power failures can occur at
any moment. The driver was executing at the moment power failed.
Power then returned, and the driver ran to completion, noticing this
error along the way. Upon exit, the driver was then officially notified of
a powerfail by MPE. The driver then attempted powerfail recovery, and
should now be operating the same as before.
2960 CLAS0001 MESSAGE: One or more bad utility parms passed to driver.
CAUSE: The driver received a utility register access request from an
upper level tool program such as PLNKUTIL, but the register number
specified was out of the range of legal register values for the selected
register set.
ACTION: This is an informational error only. This problem most likely
occurred while diagnosing some previous problem. Retry the operation
using a legal register number for the register set you have selected.
3000 CLAS0001 MESSAGE: Unable to read from adapter card PCI configuration
space.
CAUSE: During driver startup, during a restart following a reset
operation, or during processing of a utility register read request, the
driver called the I/O System to read data from an adapter register in
PCI Configuration Space, but the I/O System reported an error.
ACTION: The adapter card may have been removed, moved to a
different slot, may not be making proper contact with the PCI
backplane, or may not be responding. If the I/O slot has a power
indicator, verify it is on. Re-seat the board, and if necessary, contact
your HP Representative for hardware assistance.
3040 CLAS0001 MESSAGE: Unable to write to the adapter card PCI configuration
space.
CAUSE: During driver startup, during a restart following a reset
operation, or during processing of a utility register read request, the
driver called the I/O System to write data to an adapter register in PCI
Configuration Space, but the I/O System reported an error.
ACTION: The adapter card may have been removed, moved to a
different slot, may not be making proper contact with the PCI
backplane, or may not be responding. If the I/O slot has a power
indicator, verify it is on. Re-seat the board, and if necessary, contact
your HP Representative for hardware assistance.
3080 CLAS0001 MESSAGE: Error from upper layer protocol read completor.
CAUSE: The driver finished transferring a data frame and passed it to
an upper layer protocol, but the protocol’s read completor returned an
error which was not one of the expected, legal errors the driver was able
to handle (“Cause” = 32-bit status returned from the read completor).