NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 20 447
LAP-B Link Error Messages
LAP-B Link Driver Error Messages
ACTION: Possible actions for this problem are as follows:
1. Run the Sherlock diagnostics on the PSI and call your
Hewlett-Packard representative if there is an error.
2. Verify the configured path name is correct in NMMGR.
3. Verify that the target card is a PSI card.
1025 MESSAGE: Unsupported software model in IODC.
CAUSE: Possible causes for this problem are as follows:
1. Bad PSI hardware.
2. Wrong path name is NMMGR.
3. Wrong card type.
ACTION: Possible actions for this problem are as follows:
1. Run the Sherlock diagnostics on the PSI and call your
Hewlett-Packard representative if there is an error.
2. Verify the configured path name is correct in NMMGR.
3. Verify that the target card is a PSI card.
1026 MESSAGE: Incompatible software version in IODC.
CAUSE: The version of the PSI is not compatible with this driver.
ACTION: Write down the error information displayed on the console,
submit an CR, and call your Hewlett-Packard representative.
1027 MESSAGE: PSI did not return to a ready state after a reset was
issued.
CAUSE: Bad PSI hardware.
ACTION: Run the Sherlock diagnostics on the PSI hardware and call
your Hewlett-Packard representative if an error is detected.
1028 MESSAGE: A call to IO_CONFIG_INT failed during driver initialization.
CAUSE: Internal error.
ACTION: Write down the error information displayed on the console,
submit an CR, and call your Hewlett-Packard representative.
1029 MESSAGE: A call to IO_INIT_PFHANDLER failed during driver
initialization.
CAUSE: Internal error.
ACTION: Write down the error information displayed on the console,
submit an CR, and call your Hewlett-Packard representative.