NS3000/iX Error Messages Reference Manual (36923-90043)
534 Chapter21
Logging Location Codes
NS Configurator Logging Location Codes
NS Configurator Logging Location Codes
Several NS Configurator modules are called by the NETCP process of
Network Transport. Each of these is responsible for starting or stopping
one Transport module, and performs only those module-specific actions
which are needed.
Errors in this section apply to one or more of the following NS entities:
• 151 = IP Configurator and Deconfigurator
• 152 = UDP Configurator and Deconfigurator
• 153 = ICMP Server (PING) Configurator and Deconfigurator
• 154 = L2Resolve (NS over SNA) Configurator and Deconfigurator
• 155 = X.25 Configurator and Deconfigurator
• 156 = NI Configurator and Deconfigurator (all link types)
• 157 = PROBE Configurator and Deconfigurator
• 158 = IP Update (IPU) Configurator and Deconfigurator
• 159 = DIAL Configurator and Deconfigurator
• 160 = PXP Configurator and Deconfigurator
2 CLAS0002 MESSAGE: INTERNAL ERROR; Internal resource error
CAUSE: When NETCP attempted to create a new protocol module for an
existing NI, some specific data could not be read from the NMCONFIG
file (PARM = 16-bit status returned by the call to nmconfgetdata).
ACTION: Use NMMGR to check and validate the NMCONFIG file. Then
retry the operation. If the problem persists, see Appendix A ,
“Submitting a CR,” of this manual.
3 CLAS0002 MESSAGE: INTERNAL ERROR; Internal resource error
CAUSE: When NETCP attempted to create a new NI or a new protocol
module for an existing NI, one of the following code routines was not
found in the NL: the module itself, its Read Completor, or the FDDI
Read Completor (PARM = 32-bit status returned by the call to
hpgetsysplabel).
ACTION: Use NMMGR to check and validate the NMCONFIG file. Then
retry the operation. If the problem persists, see Appendix A ,
“Submitting a CR,” of this manual.
4 CLAS0002 MESSAGE: INTERNAL ERROR; Internal resource error
CAUSE: When NETCP attempted to create a new NI or a new protocol
module for an existing NI, after successfully creating a Port Data Area
and locating a server plabel, an error occurred while trying to create a