NS3000/iX Error Messages Reference Manual (36923-90043)

Chapter 22 629
Logging Location Codes Continued
PXP SIP Logging Location Codes
ACTION: See PATH error explanations.
34 CLAS0003 MESSAGE: None
CAUSE: A PXP socket could not be opened because the maximum
number configured has been reached.
ACTION: Increase the number of PXP sockets configured. Use the PXP
Data screen.
35 CLAS0002
CLAS0003
MESSAGE: None
CAUSE: The PXP SIP received an ICMP message from the IP module
(PARM = ICMP type word).
ACTION: None.