NS3000/iX NMMGR Screens Reference Manual - Edition 9 (36922-90040)
196 Chapter9
FDDI Network Interface Configuration Screens
Network Interface Configuration
Network Interface Configuration
The Network Interface Configuration screen (#112) in Figure 9-2 is
displayed when you press the
[Go To NI] function key at the Network
Transport Configuration Selection screen (Figure 4-2). It is also
displayed when you type the path name:
@NETXPORT.NI
in the Command window of any screen and press the [Enter] key.
Figure 9-2 Network Interface Configuration Screen
Use the fields and the function keys of the select screen to perform the
desired action.
• To define a new FDDI NI, specify an NI name and NI type FDDI;
then press the [
Add] function key. The path for the selected NI name
is added to the configuration file and the data screen on that path is
displayed. You can have a maximum of 12 NI’s per system (one
NI must be used for loopback). However, HP supports only
one active FDDI NI per system.
• To modify an existing NI configuration, specify the NI name; and
then press the
[Modify] function key. The data screen on the path for
the specified NI name is displayed.