MSL5000 and 6000 Series Tape Libraries User Guide

Troubleshooting
152 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
305B Diag Fetch, Drive not loaded
(Diag: no cartridge present for fetch.)
Press the Enter button to clear the
message.
Load a cartridge in the drive and retry the
operation.
Invalid user initiated operation. Set
parameters correctly and try again.
305D Diag Timeout waiting for drive
empty, ready
(Fetch, time-out waiting for drive unload.)
Press the Enter button to reboot.
Invalid user initiated operation. Set
parameters correctly and try again.
Ensure the drive shows good status
through the drive status window.
Check the tape cartridge used in the last
operation for damage.
305F Invalid bin number
(Invalid bin number detected in diag.)
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
3060 Zone Sequence Error
(Robot did not find sensor on power-up.)
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
3074 Drive 0 Eject Failed
(Eject command time-out.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP