MSL5000 and 6000 Series Tape Libraries User Guide
Troubleshooting
154 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
3078 Diag get drive 0 status failed
(Failed to get drive status, communication
error.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Deactivate the drive using the GUI control
panel maintenance menu.
■ Reseat drive.
■ Load/unload a cartridge to the drive to
verify.
■ Check the tape cartridge used in the last
operation for damage.
■ Run the cartridge cycle diagnostic to
verify.
3079 Diag get drive 1 status failed
(Failed to get drive status, communication
error.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Deactivate the drive using the GUI control
panel maintenance menu.
■ Reseat drive.
■ Load/unload a cartridge to the drive to
verify.
■ Check the tape cartridge used in the last
operation for damage.
■ Run the cartridge cycle diagnostic to
verify.
307A Diag get drive 2 status failed
(Failed to get drive status, communication
error.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Deactivate the drive using the GUI control
panel maintenance menu.
■ Reseat drive.
■ Load/unload a cartridge to the drive to
verify.
■ Check the tape cartridge used in the last
operation for damage.
■ Run the cartridge cycle diagnostic to
verify.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP