Intel® Centrino® 2 with vPro™ technology Setup and Configuration for HP Business Notebook PCs
 13 
so counting dashes PIDs are 9 characters and PPS are 40 characters. They must be 
generated by an S&CS. 
The Admin Password, PID, and PPS can be populated by the use of a pre-generated USB key 
generated by the ISV Management Console. 
20) Skip Un-Provision. 
For AMT 2.x, this option is to return the system to factory defaults. For AMT 4.x, the 
unprovision option in MEBx will not reset the system to factory default. See the Return to 
Default section for more information on unprovisioning. 
21) Check SOL/IDE-R. 
a.  A message window telling the user that the system resets after configuration will 
appear. 
i.  Select Y. 
b.  Username and Password 
Default Setting    : Enabled 
Recommended Setting  : Enabled 
i.  Select Enabled. 
This option allows users and passwords to be added from the WebGUI. If it is 
disabled, then only the administrator has MEBx remote access. 
c.  Serial Over LAN 
Default Setting    : Enabled 
Recommended Setting  : Enabled 
i.  Select Enabled. 
d.  IDE Redirection 
Default Setting    : Enabled 
Recommended Setting  : Enabled 
i.  Select Enabled. 
22) Skip Secure Firmware Update. 
Important Note: You may have to use the arrow keys to scroll down and see the following 
options. 
23) Go into Set PRTC. 
Default Setting    : None 
Recommended Setting  : Current Date and Time in GMT (UTC) 
This option sets the PRTC (Protected Real Time Clock). It is used with TLS mutual authentication 
which checks for the client certificate for expiration based on its PRTC. 
PRTC has a valid date range of 1/1/2004 to 1/4/2021. 
24) Skip Idle Timeout. 