Intel® Centrino® 2 with vPro™ technology Setup and Configuration for HP Business Notebook PCs
 15 
d.  HTTP Digest credentials 
e.  HTTP Negotiate credentials 
Other options can be set depending on S&CS implementation. 
33) The system goes from In-Setup phase to Operational phase. AMT is fully operational. Once in 
the Operational phase, the system can be remotely managed and can be provided to the 
end-user for regular use. 
Check with your management console supplier for information on how to prepare your Setup and 
Configuration Server. 
Return to Default
Return to Default is also know as Unprovisioning. 
An AMT Setup and Configured system can be unprovisioned. It is done through the AMT 
Configuration Screen and the Un-Provision option. 
1)  Go into Un-Provision. 
a.  Select Full Unprovision. 
Full unprovisioning is available for SMB mode provisioned systems. It will return all 
AMT Configuration settings to factory defaults. It does not reset ME Configuration 
settings or passwords. 
Full and Partial unprovisioning is available for Enterprise mode provisioned systems. 
Partial unprovisioning will return all AMT Configuration setting to factory defaults 
with the exception of the PID and PPS. It does not reset ME Configuration settings or 
passwords. 
b.  Un-provisioning message will appear. This usually takes about one minute. 
c.  After unprovisioning is done, control is passed back to the AMT Configuration 
screen. 
Notice that the Provisioning Server and Set PID and PPS options are available again 
since the system is set to the default Enterprise mode. 
2)  Return to previous menu. 
3)  Exit. 
a.  Select Y. 
4)  System will reboot. 
Important Note: The system will need to be Setup and Configured again. The system cannot be 
remotely managed until it is Setup and Configured again. 
Full Return to Factory Defaults
For AMT 2.x, once the MEBx password has been changed, the unit can not be returned to the factory 
default state without a service call. 
 For AMT 4.x, once the MEBx password has been changed, the unit can be returned to the factory 
default state by enabling the “Unconfigure AMT on next boot” option in F10. 