Owner manual

SDR EMS Messages
HP NonStop SQL DDL Replicator Users Guide545799-005
B-8
Critical Messages
Critical Messages
402
Cause. The monitor process has been intentionally abended to produce a saveabend
file for problem diagnosis.
Effect. The primary monitor process abends. The backup process takes over and
continues processing.
Recovery. Send the saveabend file to product support.
403
Cause. An operation was attempted, but no license for that service has been installed.
Effect. The operation is rejected.
Recovery. Obtain and install the necessary license.
407
Cause. The Monitor process and the Runtime have incompatible versions.
Effect. The program abends.
Recovery. Verify that the runtime library and monitor are the same version. Contact
product support for further assistance.
410
Cause. The object file is secured to prevent reading by the user id executing the
process.
Effect. The process abends.
Recovery. Resecure the object file to allow read access.
SDR monitor intentionally abended
Invalid SDR license
Version mismatch between SDR components
Error accessing object file