Owner's manual

Troubleshooting
Silo Media Manager Installation and User’s Guide541559-001
C-15
Sense Data Errors
Sense Data Errors
Sense Data messages SMM will display in EMS
NOT READY SENSE KEY CODES
If a command is sent when the library is not ready, it generates a Not Ready error
code. The following codes describe the conditions of the library that can generate
Not Ready codes.
NOT READY, CAUSE NOT REPORTABLE
SMM Message: 240: Sense Data - Not Ready, Cause Not Reportable
Explanation:
The library detected a not ready state after execution of the command was started.
NOT READY, IN PROCESS OF BECOMING READY
SMM Message: 241: Sense Data - Not Ready, In Process of Becoming Ready
Explanation:
The library is initializing and performing an audit. Initialization occurs in a
number of situations, including power-on, after the door has been opened then
closed, as part of the Send Diagnostic command, when requested from the operator
panel, and as part of a recovery during certain failures.
NOT READY, MANUAL INTERVENTION REQUIRED
SMM Message: 243: Sense Data - Not Ready, Manual Intervention Required
Explanation:
Manual intervention errors include: the front door is open, the CAP is open, the
library is in maintenance mode, or the library is in an inoperable state.
Description Sense
Key
ASC ASCQ
Not Ready, Cause Not Reportable 2h 04h 00h
Not Ready, In Process of Becoming Ready 2h 04h 01h
Not Ready, Manual Intervention Required 2h 04h 03h
Not Ready, Maintenance Mode 2h 04h 81h
Not Ready, Cartridge Access Port Open 2h 3Ah 02h
Not Ready,Cleaning Cartridge Installed 2h 30h 03h