User guide

Physical
Track ID The track ID of the switch logic board.
Part Number The part number of the switch logic board.
Hardware Revision The hardware revision of the switch logic board.
CRU Type
The type of CRU this SAC is connected to.
Values: SSAC, FSAC, SCSI
Logical
Configured Type
The type of storage device supported by this Fiber SAC.
Values: Disk, Tape, SCSI Controller, Not Configured, Unknown
Actions
Responsive Test
Verifies that the component is connected and responding.
Test Verify
Performs basic tests on the Fiber SAC. This action can be performed when the SAC is online.
FXSA / FX2SA (ServerNet/FX / ServerNet/FX2)
FRU
The ServerNet/FX adapter (FXSA) and ServerNet/FX 2 adapter (FX2SA) field-replaceable units
(FRUs) allow servers to communicate with NonStop K-series servers using a fiber-optic ring.
Location in OSM Tree: System > Group > Module > FX2SA
Slot Location: FXSA and FX2SA FRUs can be installed in slots 51 through 54 in processor, IOMF,
or IOMF2 enclosures (service side).
Example: FX2SA (41.1.53)
Attributes
FX2SA
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required. Values
Physical