User guide

Dump
Copies a memory image from a G4SA SAC to a specified file on the local system.
Firmware Update
Updates the boot firmware for the G4SASAC.
Responsive Test
Runs an online test that verifies the SAC is integrated with the LAN subsystem, is owned, and is in
the Started state.
Start
Loads the controller operational code and starts the ServerNet addressable controller. The SAC must
be in the Stopped state before you perform this action. When the Start action completes, the SAC is
in the Started state.
Stop
Rather than automatically stopping the G4SA SAC (as the Abort action does), this action first warns
you if the SAC is currently in use (and stops it only after you confirm).
Test Verify
Runs the power-on self-test for the SAC.
Group (I/O or Processor Enclosure)
A group contains all the components that are serviced by a pair of service processors (SPs). For
S-Series servers, an enclosure contains one group, and a group contains one module.
Location in OSM Tree: Under System
Examples: Group 11, Group 400
Attributes
Group
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required. Values
Logical