User guide

Power State
Whether the component is powered on. Values
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Logical
Fan Voltage The current voltage of the Fan CRU.
Main Rail Voltage
The voltage of the Main Rail, which supplies power to the CRU from its
own power supply
Disabled ServerNet Ports
This attribute indicates which, if any, ServerNet router ports on this CRU
are disabled. OSM actions to disable or enable a ServerNet port are
performed as directed by OSM alarm repair actions.
SCSI-Y Voltage
The voltage of the SCSI-Y path, the path configured for mirrored disks on
a system.
MOSFET Voltage
The voltage measured between the MOSFET switch and the diode to the
DCC. The MOSFET switch is located on the Other Rail between the
alternate power supply and the DCC.
Rail Minimum Voltage The minimum voltage (39.6 volts) that must be available to power CRU.
SCSI-X Voltage
The voltage of the SCSI-X path, the primary path used for disks on a
system.
Rail Maximum Voltage The maximum voltage limit (60 volts) for the CRU.
DCC Voltage
The operational voltage of the PMF2 CRU (specifically, the raw voltage
supplied to the DC-to-DC converters).
Other Rail Voltage
The voltage of the Other Rail, which connects the PMF/IOMF CRU to
the other power supply in the enclosure (to provide power in the event of
a problem with the Main Rail power supply).
Storage ASIC
Initialization State
The status of the storage ASIC in the CRU.
Values: Initialized, Uninitialized, Unknown
Actions
Disable ServerNet Port
Disables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.
Parameter: Port Number