User guide

Stop
Terminates operation of the SWAN concentrator and all associated SWAN CLIPs. When the Stop
action completes, the SWAN CRU and associated SWAN CLIPs are in the Stopped state.
Verify Logical Configuration
Verifies that the SWAN Concentrator CRU is properly configured. If not, an Incorrect Logical
Configuration alarm is generated on the CRU.
SWAN Battery
A subcomponent of the SWAN 2 CRU that provides backup power for 30 seconds in the event of a
power outage.
Location in OSM Tree: System > SWAN Collection > Battery
Example: Battery $ZZWAN.#SWAN2.BAT
Attributes
Battery $ZZWAN
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required. Values
Logical
Charge Status
The charge status of the SWAN 2 battery.
Values: Charging, Critical (Discharging), Unknown
Device State
The state of the component as known to the operating system on the server. Values
Actions
None.
SWAN CLIP
A communications line interface processor (CLIP) is a component of a SWAN or SWAN 2 CRU.
The CLIP provides a link-level protocol and a software interface to the host.
Each SWAN concentrator contains up to three CLIPs, and each CLIP has two WAN Lines and two
SWAN Paths.
Each SWAN 2 CRU contains up to six SWAN 2 CLIPs, and each CLIP has two WAN Lines and two