User guide

Actions
Blink LED Off
Turns off the blinking of the LED.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK NONE
Blink LED On
Causes the LED to blink on and off.
SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK ALL
Configuration Update
This action updates the configuration for the ServerNet II switch component of the 6770 switch
module. For more information, see Updating Cluster Switches.
Note: If you are updating both firmware and configuration on the same cluster switch, you
should always update the firmware first. In some circumstances, updating both
firmware and configuration is not necessary. For more information, see the
ServerNet Cluster Manual.
Optional Parameter: File name of the configuration file.
Firmware Update
Updates the firmware on the ServerNet II switch component of the 6770 switch module. For
more information, see Updating Cluster Switches.
Optional Parameter: File name of the firmware file.
Hard Reset
Is necessary following a Configuration Update action in order for the changes to take effect.
Caution: This action disrupts the ServerNet traffic through this switch.
SCF Equivalent: SCF RESET SWITCH $ZZSMN, NEAREST { X | Y }, HARD
Prepare to Replace
Must be performed from each node of a ServerNet cluster before replacing a ServerNet II
Switch for SANMAN to accept the new switch.
Replace
Launches the guided procedure for replacing a ServerNet II Switch.