User guide

Remaining Capacity Status
The remaining capacity level in the UPS batteries.
Values: Normal, Low, Depleted
If the value is Depleted, the UPS is unable to sustain the present
load if utility power is lost or absent.
Actions
Replace
Launches the Replace Switch Component guided procedure, which provides help for replacing
the component.
Common Attribute Values
Service State
This attribute appears in the list of attributes only when attention or service is required.
Value Meaning
OK
The object is functioning properly. This value appears only in the Problem
Summary dialog box.
Attention Required
The resource requires operator attention. This condition sometimes
generates an alarm, and the component that requires attention is colored
yellow in the tree pane and in the Physical and ServerNet views of the
view pane.
Service Required
The resource requires service. This condition generates an alarm, and the
component that requires service is colored red in the tree pane and in the
Physical and ServerNet views of the view pane.
Fabric State
Value Meaning
Up
At least one of the processors on the local node can communicate with at least one
processor on one of the remote nodes.
Down
No processor on the local node can communicate with a processor on any remote node.
This value is the default.
Note: The Fabric state for a one-node ServerNet cluster is Down because
communication with processors in remote nodes is not possible.