Turns the service light-emitting diode (LED) on or off for this group. Use this action to mark an
enclosure to make it easily locatable for service.
Parameter: Service LED State
on: turns LED on
off: turns LED off
Internal ServerNet Fabric
The system has two internal ServerNet fabric objects, the Internal_SvNet_X_Fabric and the
Internal_SvNet_Y_Fabric, that give you a quick synopsis of the state of the two ServerNet fabric
paths.
Location in OSM Tree: Under System
Example: Internal ServerNet Y Fabric
Attributes
Internal ServerNet Y Fabric
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required. Values
Actions
Group Connectivity ServerNet Path Test
You can perform the ServerNet Fabric action on either the Internal_SvNet_X_Fabric or the
Internal_SvNet_Y_Fabric. The test provides information on the integrity of the SP-to-SP links
between PMF/IOMF enclosures in the system.
Start ServerNet
Starts all ServerNet traffic through all or specified processors on the fabric.
Stop ServerNet
Stops all ServerNet traffic through all or specified processors on the fabric.
IOAM (I/O Adapter Module)
An I/O adapter module. There are two IOAMs in each IOAM Enclosure. For more information, see
the Modular I/O Installation and Configuration Guide.
IOAM names in OSM include the group number and a module number of either 2 or 3. For example,