Owner manual

Launches the Replace PMF guided procedure, which provides step-by-step instructions for replacing
the PMF2 CRU.
Storage ASIC Initialization Test
Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.
This action is triggered automatically when a new CRU is inserted while OSM is running or when an
SCF STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.
Test Verify
Performs some basic tests on the CRU. You can perform this action when the CRU is online.
Power Supply
The power supply converts standard AC line voltage and distributes DC power to all components in
its power domain. The power supply is:
A component of all the IOMF CRUs and PMF CRUs in NonStop S7000 servers
A separate CRU for enclosures containing IOMF2, PMF2, or PMF CRUs in NonStop S7400
or later servers
Location in OSM Tree:
Component: System > Group > Module > CRU > Power Supply
CRU: System > Group > Module > Power Supply
Slot Location:
Component: Power supplies are located within NonStop S7000 PMF CRUs and within IOMF CRUs
in slots 50 and 55 of the enclosure (service side).
CRU: Power supply CRUs are located in slots 31 and 32 of enclosures containing IOMF2, PMF2,
and PMF (NonStop S7400 or later) CRUs.
Example: Power Supply (1.1.31)
Attributes
Power Supply
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required. Values
Physical