Owner manual

Initialized
Whether the processors and service processors have been
initialized after the most recent power-on.
True: Processors and service processors have been
initialized.
False: Processors and service processors have not been
initialized.
Halt Code
The octal halt code emitted by the processor that halted.
0: No halt has occurred.
%53: System freeze occurred.
%74: Software fault occurred.
For details, see Lites Register.
Backpressure State on Internal X Fabric
Whether persistent backpressure is severe enough to
disrupt traffic on the Internal ServerNet X Fabric.
Fault: Backpressure has caused ServerNet traffic on the
Internal ServerNet X Fabric to become blocked.
OK: Backpressure levels are below the threshold level for
disrupting ServerNet traffic.
Unknown: Cannot be determined.
Backpressure State on Internal Y Fabric
Whether persistent backpressure is severe enough to
disrupt traffic on the Internal ServerNet Y Fabric:
Fault: Backpressure has caused ServerNet traffic on the
Internal ServerNet Y Fabric to become blocked.
OK: Backpressure levels are below the threshold level for
disrupting ServerNet traffic.
Unknown: Cannot be determined.
Hardware Freeze Flag
Whether the processor has been frozen by a hardware
error:
True: A hardware error in this processor caused it to
freeze. (Disregard the Halt Code and Lites Register
values.)
False: This processor has not experienced a freeze caused
by a hardware error.
Unknown: Hardware freeze state could not be read.
Online Boot Millicode Firmware
Online Boot Millicode Firmware Update is not supported for processors in S7000 PMF CRUs or on