Syntax: $volume.subvolume
Default value: $SYSTEM.SYSnn
SNDA (ServerNet/DA) CRU
The ServerNet/DA CRU (customer-replaceable unit) is an adapter that allows external storage
devices to be connected to servers. The external storage devices are physically connected to either
Fiber SACs (FSAC) or SCSI SACs (SSAC) mounted on the ServerNet/DA CRU.
Location in OSM Tree: System > Group > Module > SNDA
Slot Location: ServerNet/DA CRUs can be located in slots 53 and 54 in processor enclosures
(service side) or in slots 51, 52, 53, and 54 in I/O enclosures (service side).
Example: SNDA (12.1.54)
Attributes
SNDA
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required. Values
Physical
Power State
Whether the component is powered on. Values
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Storage ASIC
Initialization State
The status of the storage ASIC in the CRU.
Values: Initialized, Not Initialized, Unknown
Actions
Replace
Launches the Replace SNDA guided procedure, which provides step-by-step instructions for
replacing the ServerNet/DA CRU.