Owner manual

Tests two-way access to the communications line interface processor (CLIP) using the alternate
address.
Test Basic Online
Runs an online test to determine if the CLIP is functional, and checks that both the access paths are
available.
Test Full Path Access
Tests two-way access to the communications line interface processor (CLIP) using both the primary
and alternate addresses.
Test Primary Path Access
Tests two-way access to the communications line interface processor (CLIP) using the primary
address
Test Verify
Runs the power-on self-test for the CLIP. The FAULT LED on the CLIP flashes during the test. If
the test passes, the FAULT LED goes off. If the test fails, the FAULT LED remains on continuously.
SWAN Collection
When one or more SWAN concentrator CRUs are connected to a system, a SWAN Collection object
appears in both the tree pane and the overview pane of the OSM Service Connection. In both panes,
this object displays an alarm or yellow icon if alarms or degraded conditions exist on any of the
individual SWAN CRUs contained within. You can expand the SWAN Collection icon in the tree
pane (but not in the overview pane) to select and monitor individual SWAN CRUs and their
subcomponents.
Location in OSM Tree: Under System
Example: SWAN Collection
Attributes
SWAN Collection
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required. Values
Actions
None.