Owner manual

Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or
service is required. Values
Physical
CRU Type
The VA rating (volts multiplied by amps) and the firmware version of the UPS.
Example: UPS 1440 VA FW -0039
Part Number The part number of the UPS.
Logical
Estimated Charge Remaining The percentage of charge remaining in the UPS batteries.
Remaining Time
The amount of time remaining (in minutes) that the UPS battery
will provide power to the switch in the event that both the
primary and backup rails lose power, or if the input voltage of
the AC power source is not within the allowable range.
Remaining Capacity Status
The remaining capacity level in the UPS batteries.
Values: Normal, Low, Depleted
If the value is Depleted, the UPS is unable to sustain the present
load if utility power is lost or absent.
Actions
Replace
Launches the Replace Switch Component guided procedure, which provides help for replacing
the component.
Common Attribute Values
Service State
This attribute appears in the list of attributes only when attention or service is required.
Value Meaning
OK
The object is functioning properly. This value appears only in the Problem
Summary dialog box.
Attention Required
The resource requires operator attention. This condition sometimes
generates an alarm, and the component that requires attention is colored
yellow in the tree pane and in the Physical and ServerNet views of the
view pane.