Owner's manual

Chapter Two – Installation
Enter
Set-Up 1
PRESS to
Select
Tape ID:
[00]
*NOT sel
ectable*
Rwr% 0.5
Ecc: 0.5
PRESS to
alter
Exit
Set-up 1
PRESS to
Select
SCSI ID:
[00]
PRESS to
Alter
Density:
[FF]
*NOT sel
ectable*
Tape
Term:On
*NOT sel
ectable*
Figure 4 Setup 1 configuration menu
2.5.3 Select the SCSI ID screen by pushing the mode switch when the SCSI ID screen appears. This
configuration menu item allows you to set the SCSI ID. When the screen reads PRESS to
Alter, push the mode switch. The LCD shows the instruction PRESS to Increment.
On the second line of the display, the alterable digit is highlighted. To increment the digit,
push the mode switch. If no mode switch activity occurs for four seconds, the display shows
PRESS if Done, allowing you to confirm the setting. The displays returns to the Setup 1
configuration menu. Push the mode switch to exit the setup menus.
SCSI ID:
[00]
PRESS to
Alter
SCSI ID:
[01]
PRESS if
Done
SCSI ID:
[01]
PRESS to
Incremnt
Figure 5 Setting the SCSI ID
2.6 Upgrading the Firmware by Tape
To upgrade the drive firmware, insert a firmware upgrade cartridge. The process takes at least three minutes
to complete.
Caution: Do not disconnect power at any time during the upgrade process, particularly when the front
panel lights are flashing otherwise the drive may have corrupt firmware or no firmware at all.
The drive would have to be returned to the factory.
HP StorageWorks DAT 72 (Model 5242-2SE) User's Guide 6 HP Part Number 528297-003 July 2005