Manual

HP NonStop Time Synchronization User’s Guide Page 63 of 81
7. Appendix A: TimeSync Event
Messages
This appendix provides details about the event messages generated by TimeSync and
logged to the system event log. The same message numbers and descriptions apply to all
supported platforms unless otherwise stated.
7.1 General TimeSync Messages
1000
1000: TimeSync encountered an error during command line processing;
process will exit
TimeSync encountered an error while processing command line arguments and will exit.
This error only occurs during startup.
Cause. An invalid command-line argument was supplied to TimeSync.
Effect. TimeSync does not start.
Recovery. Correct TimeSync startup to remove the invalid command-line argument.
1001
1001: TimeSync could not initialize to run as a service; process will exit
TimeSync encountered an error while attempting to initialize its service infrastructure.
This error only occurs during startup.
Cause. An internal or system error occurred during service initialization. This will only
occur on Windows or Linux platforms.
Effect. TimeSync does not start.
Recovery. Validate that TimeSync is being started with correct permissions, and that the
system service configuration is correct (Windows only). If no problem is found, contact HP
support.
1002