Manual

HP NonStop Time Synchronization User’s Guide Page 67 of 81
1010: Could not obtain time source data while processing TimeSync
response; action could not be completed
TimeSync received a response from a time source, but cannot locate that time source in
the list of defined sources.
Cause. The time source was removed from the TimeSync configuration after a request
was sent to the time source, but before a response was received.
Effect. The response is discarded and the update or report operation is canceled.
Recovery. Not necessary; TimeSync will automatically retry the update using the next
configured time source.
1011
1011: Could not obtain time source data while processing multi-source
TimeSync response; reference time could be affected
TimeSync, while running with MultiSource enabled, received a response from a time
source, but cannot locate that time source in the list of defined sources.
Cause. The time source was removed from the TimeSync configuration after a request
was sent to the time source, but before a response was received.
Effect. The response is discarded and is not factored into the computed average clock
reference time used to update the local system clock.
Recovery. Not necessary; since the time source has been removed from the
configuration, subsequent updates will not utilize the time source in question.
1012
1012: Time source information could not be obtained; action could not be
completed
TimeSync could not obtain local time source information while processing an update or
report operation. Note that this message can occur even if the ReportOnly option is
enabled, since TimeSync still needs to obtain a reference time in order to calculate the
clock difference between systems.
Cause. The time source was removed from the TimeSync configuration after a response
was received from the source, but before the operation was completed.