HP NonStop Time Synchronization User’s Guide Page 69 of 81
Recovery. Define one or more time sources in the TimeSync configuration file and restart
the TimeSync process, or else specify one or more time sources interactively via the
TIMECOM ADD TIMESOURCES or SET TIMESOURCES command.
1015
1015: No valid responses were received from any time source; action could
not be completed
TimeSync, while running with MultiSource enabled, could not adjust the local system time
or complete a report operation because no valid responses were received from any of the
configured time sources. Note that this message can occur even if the ReportOnly option
is enabled, since TimeSync still needs to obtain a reference time in order to calculate the
clock difference between systems.
Cause. No time source supplied a valid reference time.
Effect. The update or report operation is canceled.
Recovery. Verify that there are no network/connectivity issues present and ensure that
there is at least one valid TimeSync or NTP time source configured. Also, if network
resources are potentially overloaded, consider increasing the MaxReplyWindow value to
give time sources more time to respond to a request.
1016
1016: Local clock differs from the time source clock source by secs seconds;
the local clock will [be adjusted | be set | will not be changed because
ReportOnly mode is enabled]
Client mode is enabled, and TimeSync is processing a local clock update. If ReportOnly
mode is enabled, the message will show the time difference but will state that the local
clock will not be updated. If ReportOnly mode is disabled and the change will be drifted
in, the message will state that the clock will be adjusted. Otherwise, if the change will not
be drifted in, the message will state that the clock will be set.
source
is the name/address of the time source from which the reference time was obtained; if
MultiSource is enabled, this value will be “<Multi>”.
secs