Manual

HP NonStop Time Synchronization User’s Guide Page 79 of 81
7.4 OSS-specific Messages
This section describes messages that are logged only on NonStop systems running the
OSS version of TimeSync. These messages will not be logged on any other platform.
4000
4000: Error obtaining system time; could not proceed with time update
TimeSync could not obtain the local system time while preparing to update the time.
Cause. TimeSync could not retrieve the current local system time while preparing to
perform a clock update. In most cases, this is a security-related issue.
Effect. TimeSync does not adjust the local system time.
Recovery. Verify that TimeSync is running with SUPER group permissions.
4001
4001: Error updating system time; could not proceed with time update -
ensure that TimeSync is running with SUPER group authority
TimeSync could not set the local system time.
Cause. TimeSync could not set the local system time. In most cases, this is a security-
related issue.
Effect. TimeSync does not set the local system time.
Recovery. Verify that TimeSync is running with SUPER group permissions.