User guide

Vendor Hardware Revision
A code that identifies the generation of the component provided by its
supplier.
Device Connection
Configured
Controller Location
The location of the configured FCSA connected to the FC-AL I/O Module.
Example: FCSA.FSAC-1.GRP-111.MOD-2.SLOT-1
Fibre Channel
Controller
The number that identifies the FCSA FSAC connected to the FC-AL I/O
Module.
Example: FCSA FSAC (111.2.1.1)
Actions
Blink LED Off
Turns off the blinking of the FC-AL I/O Modules (amber) fault LED.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED OFF
Blink LED On
Causes the FC-AL I/O Modules (amber) fault LED to blink on and off.
SCF Equivalent: SCF Control SAC $ZZSTO.#sac-name, deviceid(shelf,bay), LED ON
Replace
Displays the procedure for replacing the FC-AL I/O module.
FCDM
Attributes
Actions
Fibre Channel disk modules (FCDMs), formerly known as Disk Drive Enclosures, are located in the
OSM Service Connection tree pane hierarchy under FCMD Collection objects (see FCDM
Collection for more information on where they appear in the tree hierarchy). Each FCDM contains:
Up to 14 Fibre Channel disk drives
Two FC-AL I/O Modules
Two Power Supplies
Two Blowers
One EMU