User guide

Protect the equipment from electrostatic discharge:
Place an antistatic table mat on a flat horizontal work surface near the IOAM enclosure.a.
Put on an ESD wrist strap.b.
Attach the grounding clip from the ESD wrist strap to any unpainted metal surface on
the IOAM enclosure or on the rack in which the enclosure is installed.
Caution: Do not attach the ESD grounding clip to doors or to any painted surface.
c.
4.
Press down on the ejector to unseat the adapter. The adapter must be pulled at least two inches
out of its slot to be unseated. If the adapter is not unseated far enough, a long connector pin in
the midplane can still be engaged with the FCSA. This will make some software behave as
though the FCSA is still in its slot, but broken.
5.
Grasp the FCSA by its ejector in one hand and slowly pull the FCSA part way out of the slot.6.
Grasp the FCSA by its handle while supporting the bottom edge of the FCSA with the other
hand and pull the FCSA the rest of the way out of the slot.
Note: The FCSA weighs approximately 7.25 pounds (3 kilograms).
7.
Place the FCSA on the antistatic mat.8.
Installing the Replacement FCSA
Note: Whenever you handle a FCSA, follow standard operating practices to avoid damage to the
equipment. Review the standard operating practices documented in the Fibre Channel
ServerNet Adapter Installation and Support Guide.
Unpack and inspect the FCSA:
Put on an ESD wrist strap and attach the grounding clip to the antistatic mat.a.
Place the package containing the FCSA on the antistatic mat.b.
Open the packing container and remove the FCSA.
Caution: When opening the packing container, be careful not to cut into the ESD
protective bag.
c.
Visually inspect the FCSA and the backplane connector for damage. Use a flashlight, if
necessary, to check for bent or broken pins. If the FCSA is damaged or has a damaged
connector-pin socket, do not install it.
Caution: If you insert a FCSA that has a damaged socket into a slot, that FCSA's
backplane pins and the connectors on other adapter boards also inserted
into that slot can be damaged. Moving a damaged adapter from slot to slot
can damage other slots and other adapters.
d.
1.
Disconnect the grounding clip of your ESD wrist strap from the antistatic mat, and then
connect it to an unpainted metal surface on the FCSA.
2.