User guide

Configured Type
The configuration type of this resource.
Values: CCSA, E4SA, FESA, G4SA, GESA, TRSA, Unknown
Device State
The state of the component as known to the operating system on the server.
Values
Actions
Abort
Terminates operation of the Gigabyte Ethernet ServerNet adapter (GESA) and the associated
Ethernet ServerNet addressable controller (SAC). When the Abort action finishes, the GESA and the
SAC are in the Stopped state.
Start
Starts the Gigabyte Ethernet ServerNet adapter (GESA) and the associated Ethernet ServerNet
addressable controller (SAC). The GESA and the SAC must be in the Stopped state before you
perform this action.
During startup, the controller operational code is automatically loaded into the SAC. When the Start
action completes, both the GESA and the SAC are in the Started state.
Stop
Rather than automatically stopping the GESA (as the Abort action does), this action first warns you
if the GESA is currently in use (and stops it only after you confirm).
Group (I/O or Processor Enclosure)
Attributes
Actions
A group contains all the components that are serviced by a pair of service processors (SPs). For
S-Series servers, an enclosure contains one group, and a group contains one module.
Location in OSM Tree: Under System
Examples: Group 11
Attributes
Group
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values