User guide

Replace
Launches the Replace IOMF guided procedure, which provides step-by-step instructions for
replacing the IOMF2 CRU.
Storage ASIC Initialization Test
Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.
This action is triggered automatically when a new CRU is inserted while OSM is running or when an
(SCF) STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.
Test Verify
Performs basic tests on the CRU. You can perform this action when the CRU is online.
LIF
Attributes
Actions
The logical interface, associated with a physical interface (PIF), used by an ethernet controller port or
a ServerNet adapter port.
Location in OSM Tree:
For an Ethernet controller port LIF: System > Group > Module > PMF2 > MIOE > MIOE SAC >
MIOE PIF > LIF
For a ServerNet adapter port LIF: System > Group > Module > adapter > SAC > PIF > LIF
Example: L11021A
Attributes
LIF
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Logical
LIF State
The state of the logical interface.
Values: Started, Stopped, Unavailable