User guide

Start Monitoring UPS
Causes the OSM Service Connection to display and start monitoring the UPS. You are prompted to
enter a User ID and Password (which are established by the administrator during initial configuration
of the UPS), the IP address of the UPS, and a name (must be between 1 and 60 characters; OSM
displays this name as part of the UPS object name).
MSEB
Attributes
Actions
Modular ServerNet expansion boards (MSEBs) allow processors in one enclosure to communicate
with processors in other nodes of a ServerNet cluster on one fabric. MSEBs contain ServerNet
plug-in cards (PICs), which provide ServerNet connectivity by means of fiber-optic cables.
Each node in a ServerNet cluster must have two MSEBs for fault tolerance, one for connectivity to a
switch on the X fabric and the other for connectivity to a switch on the Y fabric.
Location in OSM Tree: System > Group > Module > MSEB
Slot Location: MSEBs must be located in slots 51 and 52 of processor enclosures (service side).
Example: MSEB (1.1.51)
Attributes
MSEB
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Power State
Whether the component is powered on. Values
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Manufacturer Identifies the manufacturer of the component.
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Logical