User guide

ME Firmware Update
Allows you to update the firmware file for the Maintenance Entity (ME) of the ServerNet Switch
Board.
Power Cycle
Power cycles the ServerNet Switch Board.
Replace
Launches the guided procedure to replace a ServerNet switch board in an IOAM or processor switch.
Set LED State
Turns the ServerNet Switch Board LED on or off.
Soft Reset
Reinitializes the firmware without affecting the ServerNet Switch Board hardware or the routing
tables.
Service Processor (SP)
Attributes
Actions
The service processor (SP) controls environmental and maintenance functions and acts as the master
of the serial maintenance bus (SMB). The service processor is a physical component of PMF, PMF2,
IOMF, and IOMF2) CRUs.
Location in OSM Tree: System > Group > Module > PMF2 > SP
Slot Location: Service processors are located on the PMF CRUs and IOMF CRUs in slots 50 and 55
of processor and I/O enclosures (service side).
Example: SP (1.1.50)
Attributes
SP
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Logical
Time of Last Reset The date and time that the service processor was last reset.