Owner's manual

Firmware
The VPROC of the firmware currently loaded on the FRU.Version
The name of the file to be used for a firmware update.Default File Name
The version of the firmware to be used for a firmware update .Default File Version
The differences, if any, between the current and default firmware versions. ValuesCompare State
Actions
Add LBU
Configures a ServerNet/FX or ServerNet/FX2 adapter as an LBU. An LBU is the SCF logical equivalent for the adapter.
Delete LBU
Removes an LBU from the system configuration database. An LBU is the SCF logical equivalent for the ServerNet/FX
or ServerNet/FX2 adapter.
Dump Controller
Writes the data from the memory of the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable unit (FRU) to the
file $SYSTEM.ZSERVICE.ZFOXDUMP.
The ServerNet/FX FRU must be in the Stopped state to perform this action.
External Loopback Test
Performs the external loopback firmware diagnostic test.
Before running this test, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2 adapter
field-replaceable unit (FRU) in the Stopped state.
Firmware Update
Updates the firmware for a ServerNet/FX adapter (FXSA) or ServerNet/FX 2 adapter (FX2SA).
Responsive Test
Verifies that the component is installed and responding.
Set FOX Cluster Number
Sets the node to which the ServerNet/FX or ServerNet/FX2 adapter FRU is connected.
Set Left Transmitter Power Level
Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.
High LED power is suitable for distances of 2 km through 4 km.
Low LED power is suitable for distances of less than 2 km.
Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2 adapter
FRU in the Stopped state.The current power level is indicated by the Left Transmitter Power Level attribute.
Set Right Transmitter Power Level
Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.
High LED power is suitable for distances of 2 km through 4 km.
Low LED power is suitable for distances of less than 2 km.
Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2 adapter
FRU in the Stopped state.The current power level is indicated by the Right Transmitter Power Level attribute.
Start
Starts the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable unit (FRU) that is in the Stopped state. During
startup, the controller operational code is automatically loaded into the FRU. When the Start action completes, the
FRU is in the Started state.
FXSA / FX2SA (ServerNet/FX / ServerNet/FX2) 135