Owner's manual

SNDA (ServerNet/DA)
The ServerNet/DA CRU (customer-replaceable unit) is an adapter that allows external storage devices to be connected
to servers.The external storage devices are physically connected to either Fiber SACs (FSAC) or SCSI SACs (SSAC)
mounted on the ServerNet/DA CRU.
Location in OSM Tree: System > Group > Module > SNDA
Slot Location: ServerNet/DA CRUs can be located in slots 53 and 54 in processor enclosures (service side) or in slots
51, 52, 53, and 54 in I/O enclosures (service side).
Example: SNDA (12.1.54)
Attributes
SNDA
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK. Values
Service State
Physical
A code that identifies the generation of the component. Hardware revision codes are
used for tracking components.
Hardware Revision
Identifies the manufacturer of the component.Manufacturer
The part number of the component that was assigned in manufacturing. Use part
numbers for identifying and ordering parts.
Part Number
Whether the component is powered on. ValuesPower State
A unique serial number that identifies the component.Track IDs are used for tracking
components.
Track ID
Storage ASIC
The status of the storage ASIC in the CRU.
Values: Initialized, Not Initialized, Unknown
Initialization State
Actions
Replace
Launches the Replace SNDA guided procedure, which provides step-by-step instructions for replacing the ServerNet/DA
CRU.
Storage ASIC Initialization Test
Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the CRU. If initialization
fails, an alarm is generated.
This action is triggered automatically when a new CRU is inserted while OSM is running or when an SCF STATUS
ADAPTER command is issued. If a CRU is inserted while OSM is not running, perform this action after logging on to
the OSM Service Connection.
Test Verify
Performs basic tests on the CRU.You can perform this action when the CRU is online.