Owner's manual

UPS (6770 Switch Module)
The uninterruptible power supply (UPS) is a component of a 6770 switch module that provides two hours of power if
both the primary and backup AC power sources fail.
Location in OSM tree:External ServerNet Fabric > Switch Group > Switch Module > UPS
Example:UPS $ZZSMN.X1
Attributes
UPS
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK. Values
Service State
Physical
The part number of the UPS.Part Number
A unique serial number that identifies the component.Track IDs are used for tracking
components.
Track ID
The VA rating (volts multiplied by amps) and the firmware version of the UPS.
Example: UPS 1440 VA FW -0039
Type
Logical
The percentage of charge remaining in the UPS batteries.Estimated Charge Remaining
The amount of time remaining (in minutes) that the UPS battery will provide power
to the switch in the event that both the primary and backup rails lose power, or if the
input voltage of the AC power source is not within the allowable range.
Remaining Time
The remaining capacity level in the UPS batteries.
Values: Normal, Low, Depleted
If the value is Depleted, the UPS is unable to sustain the present load if utility power
is lost or absent.
Remaining Capacity Status
Actions
Replace
Launches the Replace Switch Component guided procedure, which provides help for replacing the component.
264 Cluster Resources