User Manual

Error Messages
HP NonStop AutoTMF Software User’s Guide429952-014
D-5
Critical Event Messages
407
Cause. The Monitor process and the Runtime have incompatible versions.
Effect. The program abends.
Recovery. Verify that the runtime library and monitor are the same version. Contact
product support for further assistance.
410
Cause. The object file is secured to prevent reading by the user ID running the
process.
Effect. The program abends.
Recovery. Escort requires access to the object file. Re-secure the object file to allow
read access.
411
Cause. A logic error has been detected by the process.
Effect. The process abends.
Recovery. Report the error information to product support.
412
Cause. An attempt to resize the extended segment failed.
Effect. The process abends.
Recovery. The error number is provided in the message. Determine the reason for the
failure and correct it.
413
Cause. An attempt to allocate memory in the extended segment failed.
Version mismatch between the monitor and the runtime
Error reading the object file
Assertion failure
Resize segment error
Memory pool allocation error