QuickSpecs

HP Uninterruptible
Power Systems
HP Tower UPS
HP T1000 G3 UPS Models
HP T1000 G3 1000VA NA Tower Uninterruptible Power System
AF448A
HP T1000 G3 1000VA INTL Tower Uninterruptible Power System
AF449A
HP T1000J JP Uninterruptible Power System
AF457A
HP T1500 G3 UPS Models
HP T1500 G3 1400VA NA Tower Uninterruptible Power System
AF450A
HP T1500 G3 1400VA INTL Tower Uninterruptible Power System
AF451A
HP T1500J JP Uninterruptible Power System
AF458A
NOTE:
Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/13160_div/13160_div.html
(Worldwide)
HP Rack-mountable UPS
HP R1500 G3 Uninterruptible Power Supply (UPS)
HP R1.5kVA G3 1U NA Uninterruptible Power System
AF469A
HP R1.5kVA G3 1U JP/TW Uninterruptible Power System
AF470A
HP R1.5kVA G3 1U INTL Uninterruptible Power System
AF471A
NOTE:
Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/14059_div/14059_div.html
(Worldwide)
HP R/T3000 G2 Uninterruptible Power System (UPS)
HP R/T3000 G2 2U L530 Low Voltage NA/JP Uninterruptible Power System
AF466A
HP R/T3000 G2 2U L620 High Voltage NA/JP Uninterruptible Power System
AF467A
HP R/T3000 G2 2U Detachable Cord High Voltage INTL Uninterruptible Power
System
AF468A
NOTE:
Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/14058_div/14058_div.html
(Worldwide)
NOTE:
For additional information on HP Uninterruptible Power Systems please go
to:
www.hp.com/servers/rackups
.
NOTE:
For additional information on sizing your server, please reference:
http://www.upssizer.com
.
Please see the UPS and PDU cable matrix's on the HP Power Protection and
Management page. Under Power Cords, click on the "HP Power Cord Matrix" link.
That link will list cable descriptions, requirements, and specifications for UPS and
PDU units. Please see the following link:
www.hp.com/products/powercords
.
HP Power Distribution
Units
Modular Power Distribution Units 1U/0U (Up to 32 outlets)
NOTE:
1U/0U mounting brackets shipped with the unit (optimized for 10000 and
9000 series racks).
HP 4.9kVA 24A High Voltage NA/JP Modular Power Distribution Unit
252663-D72
HP 8.3kVA 40A High Voltage NA/JP Modular Power Distribution Unit
252663-D73
HP 7.3kVA 32A High Voltage INTL Modular Power Distribution Unit
252663-B31
HP 3.6kVA 16A High Voltage INTL Modular Power Distribution Unit
NOTE:
This PDU has a detachable input power cord and allows for adaptability to
country specific power requirements.
252663-B24
NOTE:
Please see the following QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html
(Worldwide)
NOTE:
For additional information on HP Power Distribution Units including
accessories please go to:
www.hp.com/go/pdu
.
Please see the UPS and PDU cable matrix's on the HP Power Protection and
Management page. Under Power Cords, click on the "HP Power Cord Matrix" link.
That link will list cable descriptions, requirements, and specifications for UPS and
PDU units. Please see the following link:
www.hp.com/products/powercords
.
HP Rack Series
HP Rack 10000 G2 Series
(Carbon/Graphite Metallic)
HP 10642 G2 Pallet Universal Rack
AF001A
HP 10642 G2 Shock Universal Rack
AF002A
HP 10642 G2 1200mm deep Shock Rack
AF092A
HP 10647 G2 1200mm deep Shock Rack
AF094A
NOTE:
It is mandatory to use a shock pallet when shipping racks with equipment
installed.
NOTE:
Please see the QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide)
NOTE:
For additional information regarding Rack Cabinets and Telco Rack
support, please see the following URL:
http://www.hp.com/go/rackandpower
.
NOTE:
The increasing power of new high-performance processor technology
requires increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks to be
fully loaded with servers using the latest processors.
CAUTION:
If a third-party rack is used, observe the following additional
requirements to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors,
you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from
top to bottom to permit adequate airflow (equivalent to the required 64 percent
open area for ventilation). Side: The clearance between the installed rack
component and the side panels of the rack must be a minimum of 2.75 inches (7
cm).
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-
spaces in the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
NOTE:
Quick deploy rail system provides tool-free support for racks with square
or round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP
series), with an adjustment range of 24" - 36". The ambidextrous cable
management arm can be mounted on either the left or right side for improved cable
management.
QuickSpecs
HP ProLiant DL370 Generation 6
Additional Options
DA - 13242 Worldwide QuickSpecs — Version 48 — 1/13/2012