QuickSpecs
System Unit
Tower Dimensions
(H x W x D) (with bezel)
18.52 x 9.75 x 29.12 in (47.04 x 24.77 x 73..96 cm)
Rack Dimensions
(H x W x D) (with bezel)
6.88 x 19.03 x 27.53 in (17.48 x 48.34 x 69.93 cm)
Tower Weight
(approximate)
Maximum
(All hard drives, power
supply, and processor
installed)
96.34 lb (43.70 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
66.14 lb (30.00 kg)
Rack Weight
(approximate)
Maximum
(All hard drives, power
supply, and processor
installed)
85.69 lb (38.87 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
55.12 lb (25.00 kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 - 132 VAC,
180 - 264 VAC
Rated Input Current
7.5A (at 100 VAC),
3.8A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
980W (at 100 VAC)
1035W (at 120 VAC)
1170W (at 240 VAC)
BTU Rating
Maximum
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600 (at
240 VAC)
Power Specifications
To review typical system power ratings use the HP Power Advisor which
is available via the online tool located at URL:
www.hp.com/go/proliant-
energy-efficient
- Click on the system of interest. Example: DL370 G6 or ML370 G6
- Follow the instructions of the next screens.
Power Supply Output
(per power supply)
Rated Steady-State
Power
460 W (at 100 VAC)
Maximum Peak Power
460 W (at 200 VAC)
460 W (at 100 VAC)
460 W (at 200 VAC)
NOTE:
See Power Supply Specifications
tables for complete details on 460W PSU and
optional 750W and 1200W Power Supply
Options.
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
10 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109).
Idle
L WAd
4.6 B for 1P Non-Redundant; 4.9 B for 2P
Redundant
L pAm
28 dB for 1P Non-Redundant; 31 dB for 2P
Redundant
Operating
L WAd
4.7 B for 1P Non-Redundant; 5.0 B for 2P
Redundant
L pAm
29 dB for 1P Non-Redundant; 32 dB for 2P
Redundant
NOTE:
The Listed sound levels apply to standard shipping configurations.
Additional options may result in increased sound levels.
Emissions
Classification
(EMC)
FCC Rating
Class B
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1
NOTE:
Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and
statements.
QuickSpecs
HP ProLiant DL370 Generation 6
Technical Specifications
DA - 13242 Worldwide QuickSpecs — Version 48 — 1/13/2012
Page 26