User Guide

Component identification 16
Systems Insight Display
LED and color
Internal health
LED color
Status
FBDIMM failure, all slots in
all banks (amber)
Red
One or more FBDIMMs has failed. Test each bank of
FBDIMMs by removing all other FBDIMMs. Isolate the
failed FBDIMM by replacing each FBDIMM in a bank with
a known working FBDIMM.
Online spare memory
(amber)
Amber Bank X failed over to the online spare memory bank.
Online spare memory
(flashing amber)
Red Invalid online spare memory configuration.
Online spare memory (green) Green Online spare memory enabled and not failed.
Mirrored memory (amber) Amber Bank(s) X failed over to the mirrored memory bank(s).
Mirrored memory (flashing
amber)
Red Invalid mirrored memory configuration.
Mirrored memory (green) Green Mirrored memory enabled and not failed.
Overtemperature (amber) Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Riser interlock (amber) Red PCI riser cage is not seated.
Fan (amber) Amber One fan is failed or removed.
Red Two or more fans have failed or are removed.
SAS device numbers