Specifications
Table Of Contents
- HP ProLiant ML350 Generation 4 Server Maintenance and Service Guide
- Notice
- Contents
- Illustrated parts catalog
- Removal and replacement procedures
- Required Tools
- Safety considerations
- Preparation procedures
- Removing tower feet
- Removing the front bezel (tower model)
- Rack rails
- Removing the power supply blank
- Hot-plug power supply
- Non-hot-plug power supply
- Hot-Plug Power Supply Backplane
- Removing a hard drive blank
- Hot-Plug SCSI Hard Drive
- Non-hot-plug SCSI hard drive
- Redundant system fan
- Expansion Slot Cover
- Expansion board
- CD-ROM drive
- Tape drive
- Internal two-bay hot-plug SCSI drive cage
- Processor and Heatsink
- PPM
- Second serial port
- Duplex SCSI backplane
- Battery
- System Board
- Re-entering the server serial number and product ID
- Diagnostic tools
- Server component identification
- Specifications
- Acronyms and abbreviations
- Index

Specifications 47
Specification Value
Rated steady-state power 460 W
Maximum peak power 484 W
Acoustic Noise
Idle <6.5 and 48
Operating <6.5 and 48
Environmental specifications
Specification Value
Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Shipping -40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating 10% to 90%
Non-operating 5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Rack server specifications
Specification Value
Height 21.87 cm (8.61 in)
Depth (with bezel) 60.96 cm (24 in)
Width 48.26 cm (19 in)
Weight (no drives installed) 27.24 kg (60 lb)
Models with a redundant
power supply
Input requirements
Rated input voltage 100 VAC to 240 VAC
Rated input frequency 47 Hz to 63 Hz
Rated input current 10 A (110 V) to 5 A (220 V)
Rated input power 893 W
BTUs per hour 3049
Power supply output
Rated steady-state power 725 W
Maximum peak power 725 W
Models with a Non-
redundant power supply