Technical data

Listing and Managing Server Hardware
Power Status for Hardware Components
HP System Partitions Guide: Administration for nPartitions, rev 5.1
321
Cabinet Power—Whether the 48-volt cabinet power switch is on or
off, whether cabinet power is enabled, and details about power
boards and bulk power supplies.
Cell Power—Whether power is enabled and on for all cells within
the cabinet.
Core I/O Card Power—Whether power is enabled and on for all
core I/O cards within the cabinet.
For system complexes that have multiple cabinets, you must check
details for each cabinet separately.
You also can use the PS command to check individual cell (C) or core I/O
(I) hardware and power status.
The following example shows cabinet power details for cabinet 0 of an
SD64000 model Superdome server.
Select Device: b
Enter cabinet number: 0
HW status for SD64000 compute cabinet #0: NO FAILURE DETECTED
Power switch: on; Power: enabled, good; Door: closed
Fan speed: normal; Temperature state: normal
Redundancy state: fans or blowers redundant, BPSs redundant
| Main BP| | IO Backplanes |
| Power | | IO Bay 0 | IO Bay 1 |
| Main | Boards | Cells | Chassis | Chassis |
| BP | 0 1 2 | 0 1 2 3 4 5 6 7 | 0 1 2 3 | 0 1 2 3 |
+--------------+------+--------+-----------------+----------+----------+
Populated | * | * * * | * * * * * * * * | * * | |
Power Enabled | * | * * * | * * * * * * * * | * * | |
Powered On | * | * * * | * * * * * * * * | * * | |
Power Fault | | | | | |
Attention LED | | | * | * | |
| Cabinet | IO |
| BPS | Blowers | Fans |
| 0 1 2 3 4 5 | 0 1 2 3 | 0 1 2 3 4 |
+-----------+-------------+---------+-----------+
Populated | * * * * * | * * * * | * * * * * |
Failed | | | |